Festo AG & Co. KG
1577012
electrical interface
CPX-CTEL-4-M12-5POL
More detailed information about this product!
Festo Data sheet
Criterion | Feature |
Dimensions W x L x H | (including interlinking block) 50 mm x 107 mm x 55 mm |
Number of device interfaces | 4 |
Diagnosis | Communication error Short circuit module Module-oriented diagnostics Undervoltage |
Parameters configuring | Diagnostics behaviour Fail-safe mode per channel Forcing per channel Idle mode per channel Module parameter Tool change mode |
Additional functions | Tool change mode |
Control elements | DIL switches |
LED displays | I-Port status/diagnostics Module status Status load voltage Status system supply |
Internal cycle time | 1 ms per 1 byte of user data |
Operating voltage range DC | 18 - 30 V |
Intrinsic current consumption at operating voltage | Typ. 65 mA |
Max. power supply per channel | 4 x 1,6 A |
Max. resultant current of outputs per channel | 4 x 1,6 A |
Nominal operating voltage DC | 24 V |
Power failure buffering | 10 ms |
Electrical isolation channel – internal bus | Yes, for intermediate supply |
Electrical isolation channel – channel | No |
Corrosion resistance classification CRC | 1 - Low corrosion stress (when installed) |
Storage temperature | -20 - 70 °C |
Protection class | IP65 IP67 |
Ambient temperature | -5 - 50 °C |
Product weight | 110 g |
Maximum address volume for outputs | 32 Byte |
Maximum address volume for inputs | 32 Byte |
Protocol | I-Port |
Max. line length | 20 m |
Electrical connection | 4x socket M12 5-pin A-coded |
Materials note | Conforms to RoHS |
Material housing | PA-reinforced PC |
© 2020 Festo AG & Co. KG