Festo AG & Co. KG

1577012
electrical interface
CPX-CTEL-4-M12-5POL

More detailed information about this product!

Festo Data sheet

CriterionFeature
Dimensions W x L x H(including interlinking block)
50 mm x 107 mm x 55 mm
Number of device interfaces4
DiagnosisCommunication error
Short circuit module
Module-oriented diagnostics
Undervoltage
Parameters configuringDiagnostics behaviour
Fail-safe mode per channel
Forcing per channel
Idle mode per channel
Module parameter
Tool change mode
Additional functionsTool change mode
Control elementsDIL switches
LED displaysI-Port status/diagnostics
Module status
Status load voltage
Status system supply
Internal cycle time1 ms per 1 byte of user data
Operating voltage range DC18 - 30 V
Intrinsic current consumption at operating voltageTyp. 65 mA
Max. power supply per channel4 x 1,6 A
Max. resultant current of outputs per channel4 x 1,6 A
Nominal operating voltage DC24 V
Power failure buffering10 ms
Electrical isolation channel – internal busYes, for intermediate supply
Electrical isolation channel – channelNo
Corrosion resistance classification CRC1 - Low corrosion stress
(when installed)
Storage temperature-20 - 70 °C
Protection classIP65
IP67
Ambient temperature-5 - 50 °C
Product weight110 g
Maximum address volume for outputs32 Byte
Maximum address volume for inputs32 Byte
ProtocolI-Port
Max. line length20 m
Electrical connection4x socket
M12
5-pin
A-coded
Materials noteConforms to RoHS
Material housingPA-reinforced
PC

© 2020 Festo AG & Co. KG